Copper has excellent physical, thermal properties and electrical conductivity. Copper is easily soldered, welded and plated for corrosion resistance.
Gold plated pure copper is used when electrical conductivity is crucial and its application is critical to maintaining a stable resistance with minimal variation over the wire length.
Copper is available in three grades of Oxygen free (OF), Oxygen free electronic (OFE) and also in grade Electrolytic Tough Pitch (ETP), in both round and milled ribbon forms.
Chemical composition
| Cu % | Ag % |
C10100 OFE Oxygen free electronic |
99.99 |
- |
C10200 OF Oxygen free |
99.99 |
min |
Table represents nominal composition of each grade
Mechanical properties
| Tensile strength Rm |
| MPa | ksi |
Hard |
455 |
66 |
Annealed |
220 |
32 |
Physical properties
Density g/cm3 (lb/in3) |
8.94 (.323) |
Electrical resistivity at 20°C Ωmm2/m (Ω circ. mil/ft) |
0.017 (10.2) |
Temperature coefficient of resistance K-1 |
+0.00397 |
Conductivity at 20°C (68°F) |
Anealed 101% IACS min |
Coefficient of thermal expansion
Temperature °C (°F) |
Thermal expansion 10 -6/K (10 -6/°F) |
20-500 (68-932) |
17.0 (9.4) |
Thermal conductivity
Temperature °C (°F) |
100 (212) |
W m-1 K-1 (Btu h-1 ft-1 °F-1) |
391 (226) |
Specific heat capacity
Temperature °C (°F) |
20 |
kJ kg-1 K-1 (Btu lb-1 °F-1) |
0.385 (0.092) |
Melting Point °C (°F) |
1083 (1981) |
Standards
Specifications |
ASTM B170, 1, 2, 3, F-68, 272-grade 1 and 2 |